AZ Bluetooth Hub

The AZ Bluetooth Hub adds global connectivity to any WinCE HMI running AZ System software.

Using a regular Android device, the HMI gains SMS and Email function, without configuring any difficult APN's or other mobile settings.

Send SMS from HMI using an Android phone

The Android APP is available for any device running Android 6 and above, it can be downloaded from the play store.

 

 

AZ Modbus Updated

The AZSystem Modbus Driver now fully supports the Sierra Instruments 640i QuadraTherm Flow Meter.

The addition of this device, provides limitless possibilities, f.i.:

  • multi point flow measurement
  • valve control
  • data logging
  • and much more!

AZ Power Control

AZ Power Control - for building your own master-slave power strip

When you switch on your PC, most of the time, you also need to switch on other devices. In the A.Z. System philosophy, this should be automated.

Now you can! Using the A.Z. Power Control!

The A.Z. Power Control uses a 2 channel usb powered relay module, switching on when the computer starts, and switches off when the computer shuts down.

Just that easy.

The A.Z. Power Control switches both, phase and neutral for maximum safety. At a max of 16A/230VAC.

See the download section for the free software

A.Z. Dynamic Modbus Protocol

AZ System Dynamic Modbus RTU Protocol

A.Z. Dynamic Modbus Protocol allows a network of Modbus Devices with different communication settings to communicate on 1 network.
This is very useful when a network consists mainly of fast devices and one or two slow devices.
Other SCADA solution providers only support 1 communication setting. One communication setting results in the speed of the total network determined by the slowest device.
For instance if a network consists of 10 fast devices and 1 slow device, the fast devices need to be set to the slow communication setting. Resulting in a slow network, low sample rates and slow responses.

With A.Z. Dynamic Modbus Protocol only the slow devices is addressed at a slow rate, the others are addresses at full speed.

A.Z. Dynamic Modbus Protocol is available for Windows PC and WinCE6

 

Example network settings:

 

Traditional Modbus RTU Driver

 

A.Z. Dynamic Modbus Protocol

Device

1 (fast)

2 (fast)

3 (slow)

 

1 (fast)

2 (fast)

3 (slow)

Baud

9600

9600

9600

 

115k2

115k2

9600

Parity

N

N

N

 

E

E

N

Databits

8

8

8

 

8

8

8

Stopbits

1

1

1

 

1

1

1

Available from version 2.2.0.0 (beta)

AZeUpdate

All AZSystem Products now Support AZe Update (easy update)

From now on all AZSystem firmware (for WinCE HMI) comes with AZeUpdate (pronounced as Eazy Update).

AZeUpdate provides online firmware update, with just one click on the touch screen.

AZeUpdate is secure and fail-safe! The AZeUpdate-pack (package needed for performing an update) is verified by multiple layers of security and the AZePackage is dedicated for one device only. No mixups can occure, the AZePackage is only allowed to install on the specific device it is intended for.

Each system receives it's own specific, dedicated updates.

The AZeUpdate can also be performed unattended (only when internet connection is available and when 1 minute of downtime at any time is allowed).

In case no internet connection is available, the update AZeUpdate-pack can be delivered to the system by using a USB stick. Once the USB is inserted into the system, just one click is required to perform the firmware update.

One Click: AZeUpdate.